How to solve a limit condition in Casswrap (by Rolando Rogers).
The procedure to recover from a CRCS wrap limit fault is the following:
1. Go to 4th floor to visually inspect the cass rotator cable chains and make sure nothing is broken.
2. Dissasert the CRCS in the dm screen (THIS IS VERY IMPORTANT to do, otherwise you will continue getting the fault as soon as you reset GIS)
3. While in the 4th floor, reset GIS faults by pushing F1 in AB display
4. Then issue a CENTERWRAP command form the dm screens. PLEASE NOTE that you DON’T need to assert the drives, the centerwarp command will do it for you.
5. Wait till the command is over and go to IDLE state after 2 or 3 minutes.
6. Reset GIS AB display again.
7. You are ready to go and you don’t need to assert the drives again as the centerwrap command did it for you.